EOS EMOTEC B6000 Manuale di Servizio Pagina 24

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 60
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti
Vedere la pagina 23
24
GB
Package contents
(subject to change)
Included with the control unit are:
1. An heater-sensor board with overheat shutoff protection, KTY-sensors with sensor housing
, two 3x25 mm fastening screws and a 2,0 m long sensor cable, red and white.
2. A plastic bag with three 4 x 20 mm fastening screws.
3. A replacement overheat protection module.
Technical data
Rated voltage: 400 V 3 N 50 Hz AC
Schaltleistung: max 9 kW resistive load (AC 1 operation)
upgrade to 36 kW possible through connection to power cont-
rol units
Heating time shut-off: 6 h
Display: LCD, backlit
Protection type: IPx4 in accordance with EN 60529, splashproofi ng
Control range,
sauna operation: 30 to 115°C
Sensor system: KTY-Sensor with overheat shutoff protection at 142° C
Control characteristics: digital two-step control
Fan capacity:: max. 100 W, max. 450 mA (only fan without capacitor)
Light: max. 100 W, max. 450 mA (only ohm resistive load)
Error display: blinking warning triangle and error code on LCD
Environmental temperature:-10°C to +30°C
Storage temperatures: -20°C to +70°C
Vedere la pagina 23
1 2 ... 19 20 21 22 23 24 25 26 27 28 29 ... 59 60

Commenti su questo manuale

Nessun commento